CLAAS Jaguar Tractor Fault Codes DTC
Code Module Fault Operating state Troubleshooting
E-1
Device CAB oil pressure engine too poor
E-2
Device CAB Oil Level engine too low
E-3
Unit CAB Water pump defective
Charging Control lights and goes out.
Test drive water pump and generator.
Check control charge on generator
E-4
CAB Temperature cooling water too high
E-5
CAB hydraulic temperature
Coil too high
E-6
CAB Tighten the handbrake
E-8
Electric Hydraulic
First drive running of the EFA
Wrong voltage potentiometer supply of movement
E-11
Apparatus CAB pressure hydraulics
Coil or oil level is too low
E-12
Apparatus CAB
Temperature charge air too high
E-13
Metal detector ESR defective
E-14
ESR Metal detector interrupt
E-15
Apparatus CAB Reserve CAB
E-16
ESR still connected adapter box SFM
(Note: SFM self-propelled mower)
When necessity check configuration (SFH or SFM).
E-19
Apparatus CAB
Hydraulic drive motor
Coil not complies configuration
E-20
Ellectric Hydraulic
First drive running of the EFA new module EFA absolutely necessary potentiometer study movement of the lever
This message appears after installing a new
EFA module when the ignition.
After learning
potentiometers arm and hydraulic motion flow this message no longer appears.
1. Study potentiometer
movement of the lever
2. Study hydraulic flows through
CDS system
Hydraulic oil should have labor temperature. meaning voltage pressure sensors should be < 1.2 V.
E-17
Numbers of revolutions ESR Sensor feeder defective
Check plug to compound sensor and cable compound.
E-18
Numbers of revolutions ESR Sensor feeder defective
Check plug to compound sensor and cable compound.
E-25
ESR fault downstream hydraulic pump feeder
E-27
Electric Hydraulic
First drive running of the EFA
Defective valve output PWM trailer brakes
E-30
In ESR Valves stop permanently energized
E-32
CAB CAN-Bridge Module defective
Check power module.
Check strength landing and contact conclusions.
E-33
ESR ESR module defective. Check power module.
Check strength landing and contact conclusions.
E-34
AutoContour CAC module outline faulty system
Check power module.
Check strength landing and contact conclusions.
E-36
GGS GGS Defect Test power module.
Check strength landing and contact conclusions.
E-37
Electrical Hydraulic
First drive running of the EFA
EFA faulty module Emergency stop:
During this work It indicates a defect power module output. It should be shut down.
The movement of the machine no more provided
possible.
Turn off the machine and restart, if the fault no more It appears, in another module procedure, otherwise. If not, replace module.
E-38
Control Unit valve defective
E-39
ATP reserve, autopilot
E-40
First drive running of the EFA
Faulty valve hydraulic pump
Emergency mode: machine moves only reversing at speeds OK. 2 km / h at the 2nd Transfer 1 km / h in the 1st transmission.
When you identify short the closure of the valve It made an emergency
Stop the movement over impossible. flap impossible
to govern:
Check cable Connect to valve. Check the module output. Measure resistance coil range values: 6 - 12 ohms
Check plug to compound valve.
E-42
First drive running of the EFA Faulty third magnet
electromagnetic valve
Emergency Stop:
The machine moves on coast to stop, further movement is not provided possible. flap impossible
to govern:
Check cable module connection to the valve for a short circuit or breakage. Check the module output.
measure resistance coil range values: 6 - 12 ohms
Check plug to compound valve.
E-43
First drive running of the EFA
Defect electromagnetic pump valve motion ago
Emergency mode:
The machine moves only forward at approx. 2
km / h at the 2nd transmission 1 km / h on the 1st gear.
When you identify short the closure of the valve
It made an emergency. Stop the movement over
impossible. flap impossible to govern:
Check cable module connection to the valve for a short circuit or breakage. Check the module output.
measure resistance coil range values: 6 - 12 ohms
Check plug to compound Valve.
E-41
First drive running of the EFA Faulty electromagnetic hydraulic valve engine
Limited exploitation:
Steer until Max. 7 km / h on the 1st transmission,
12 km / h on the 2nd transfer flap
mpossible to govern:
Check cable module connection to the valve for a short circuit or breakage. Check the module output.
measure esistance coil range values: 6 - 12 ohms
Check plug to compound valve.
E-44
CAB Out of order communication engine system
No CAN bus to module ADM.
The module works wrong.
Check power modules. Check cable trunk to modules (terminals).
E-45
Grinder GGS not in the initial position
E-46
First drive running of the EFA
Faulty lever potentiometer of movement
Emergency mode:
The car moves with speed 1 km / hr only in the forward direction.
(Identification of areas movement through neutral switch position and the switch
Reverse) Potentiometer movement of the lever
It is in the form double potentiometer.
E-46
Check cable set to module potentiometer on open or short circuiting.
Potentiometer
Motion 2 issues opposite signal sum with which the signal potentiometer
Motion 1 is always must have permanent value.
If the total signal is not in within 7.3 - 7.5, the potentiometer movement of the lever defective.
Example:
Signal 1 = 4.0 V
Signal 2 = 3.4 V>
Amount: 4.0 + 3.4 = 7.4 B => potentiometer order.
Signal 2 = 1.0 =>
Amount: 4.0 + 1.0 = 5.0 B => potentiometer defective
measure potentiometer.
E-50
ESR does not recognize the adapter SFM box
The module identifies the ESR speed sensors
Rotation Disco 8500, but 5 are absent from adapter box.
Female compound: Check 13 pin connector on the
driver site (corrosion). Open or short closing signal wire to the ESR module.
E-51
The level of coolant the water is too low
Refuel cooling water.
Cable set or plug cause short short to ground.
E-52
ESR No recognition rotation speed feeder
Fault can be issued in multiple without reversing
causes.
When submitting a feed the device is switched off
after the issuance of reports malfunction.
Check plug to compound speed sensor rotation.
Check 13 pin connector on the driver site (corrosion).
Open or short closing signal wire to the ESR module.
E-47
First drive running of the EFA exceeded tolerance
lever potentiometer of movement
Unusual behavior movement.
No, the final speed.
Despite the return of movement of the lever ago
speed reduction initially not made (Slow response).
Only the issue of a code, the behavior of the motion is not changes.
Potentiometer movement of the lever It is in the form double potentiometer: permissible meaning
potentiometer
Motion 1:
Neutral Situation: 3,8 - 4.2V
Next: 6.9 - 7.3 in
Previous: 0.8 - 1.2 V
Potentiometer Motion 2 issues opposite signal sum
with which the signal potentiometer
Motion 1 is always must have permanent value.
If the total signal is not in within a predetermined
range, lever potentiometer of movement defective.
E-48
In the feed ESR Metal device
The delivery device It stands load metal detector.
Remove the metal. Is not fault in sense of the word.
E-49
ESR Stop slip clutch consoles
STB is turned off. Post without overload:
Check cable set and to console her.
Check sensor rotation speed prefix.