Claas Tractor logo

CLAAS Jaguar Tractor Fault Codes DTC


Download
CLAAS Jaguar Fault Codes DTC
CLAAS Jaguar Fault Codes DTC
CLAAS Jaguar Fault Codes DTC.pdf
Adobe Acrobat Document 288.4 KB

CLAAS Jaguar Tractor Fault Codes DTC

 

Code Module Fault Operating state Troubleshooting

 

E-1

Device CAB oil pressure engine too poor

 

E-2 

Device CAB Oil Level engine too low

 

E-3

Unit CAB Water pump defective

Charging Control lights and goes out.

Test drive water pump and generator.

Check control charge on generator

 

E-4

CAB Temperature cooling water too high

 

E-5

CAB hydraulic temperature

Coil too high

 

E-6

CAB Tighten the handbrake

 

 

E-8

Electric Hydraulic

First drive running of the EFA

Wrong voltage potentiometer supply of movement

 

E-11 

Apparatus CAB pressure hydraulics

Coil or oil level is too low

 

E-12

Apparatus CAB

Temperature charge air too high

 

E-13

Metal detector ESR defective

 

E-14

ESR Metal detector interrupt

 

E-15 

Apparatus CAB Reserve CAB

 

E-16

ESR still connected adapter box SFM

(Note: SFM self-propelled mower)

When necessity check configuration (SFH or SFM).


E-19 

Apparatus CAB

Hydraulic drive motor

Coil not complies configuration

 

E-20

Ellectric Hydraulic

First drive running of the EFA new module EFA  absolutely necessary potentiometer study movement of the lever

This message appears after installing a new

EFA module when the ignition.

After learning

potentiometers arm and hydraulic motion flow this message no longer appears.

1. Study potentiometer

movement of the lever

2. Study hydraulic flows through

CDS system

Hydraulic oil should have labor temperature. meaning voltage pressure sensors should be < 1.2 V.

E-17 

Numbers of revolutions ESR Sensor feeder defective

Check plug to compound sensor and cable compound.

 

E-18 

Numbers of revolutions ESR Sensor feeder defective

Check plug to compound sensor and cable compound.

 

E-25

ESR fault downstream hydraulic pump feeder

 

E-27

Electric Hydraulic

First drive running of the EFA

Defective valve output PWM trailer brakes

 

E-30

In ESR Valves stop permanently energized

 

E-32

CAB CAN-Bridge Module defective

Check power module.

Check strength landing and contact conclusions.


E-33

ESR ESR module defective. Check power module.

Check strength landing and contact conclusions.

 

E-34

AutoContour CAC module outline faulty system

Check power module.

Check strength landing and contact conclusions.

 

E-36 

GGS GGS Defect Test power module.

Check strength landing and contact conclusions.

 

E-37

Electrical Hydraulic

First drive running of the EFA

EFA faulty module Emergency stop:

During this work It indicates a defect power module output. It should be shut down.

The movement of the machine no more provided

possible.

Turn off the machine and restart, if the fault no more It appears, in another module procedure, otherwise. If not, replace module.

E-38

Control Unit valve defective

 

E-39

ATP reserve, autopilot

 

E-40

First drive running of the EFA

Faulty valve hydraulic pump

Emergency mode: machine moves only reversing at speeds OK. 2 km / h at the 2nd Transfer 1 km / h in the 1st transmission.

When you identify short the closure of the valve It made an emergency

Stop the movement over impossible. flap impossible

to govern:

Check cable Connect to valve. Check the module output. Measure resistance coil range values: 6 - 12 ohms

Check plug to compound valve.


E-42

First drive running of the EFA Faulty third magnet

electromagnetic valve

Emergency Stop:

The machine moves on coast to stop, further movement is not provided possible. flap impossible

to govern:

Check cable module connection to the valve for a short circuit or breakage. Check the module output.

measure resistance coil range values: 6 - 12 ohms

Check plug to compound valve.

 

E-43

 

First drive running of the EFA

Defect electromagnetic pump valve motion ago

Emergency mode:

The machine moves only forward at approx. 2

km / h at the 2nd transmission 1 km / h on the 1st gear.

When you identify short the closure of the valve

It made an emergency. Stop the movement over

impossible. flap impossible to govern:

Check cable module connection to the valve for a short circuit or breakage. Check the module output.

measure resistance coil range values: 6 - 12 ohms

Check plug to compound Valve.

E-41

First drive running of the EFA Faulty electromagnetic hydraulic valve engine

Limited exploitation:

Steer until Max. 7 km / h on the 1st transmission,

12 km / h on the 2nd transfer flap

 mpossible to govern:

Check cable module connection to the valve for a short circuit or breakage. Check the module output.

measure esistance coil range values: 6 - 12 ohms

Check plug to compound valve.

 

E-44 

CAB Out of order communication engine system

No CAN bus to module ADM.

The module works wrong.

Check power modules. Check cable trunk to modules (terminals).

 

E-45

Grinder GGS not in the initial position

 

E-46

First drive running of the EFA

Faulty lever potentiometer of movement

Emergency mode:

The car moves with speed 1 km / hr only in the forward direction.

(Identification of areas movement through neutral switch position and the switch

Reverse) Potentiometer movement of the lever

It is in the form double potentiometer.

 


E-46

Check cable set to module potentiometer on open or short circuiting.

Potentiometer

Motion 2 issues opposite signal sum with which the signal potentiometer

Motion 1 is always must have permanent value.

If the total signal is not in within 7.3 - 7.5, the potentiometer movement of the lever defective.

Example:

Signal 1 = 4.0 V

Signal 2 = 3.4 V>

Amount: 4.0 + 3.4 = 7.4 B => potentiometer order.

Signal 2 = 1.0 =>

Amount: 4.0 + 1.0 = 5.0 B => potentiometer defective

measure potentiometer.

 

E-50

ESR does not recognize the adapter SFM box

The module identifies the ESR speed sensors

Rotation Disco 8500, but 5 are absent from adapter box.

Female compound: Check 13 pin connector on the

driver site (corrosion). Open or short closing signal wire to the ESR module.

 

E-51

The level of coolant the water is too low

Refuel cooling water.

Cable set or plug cause short short to ground.

 

E-52

ESR No recognition rotation speed feeder

Fault can be issued in multiple without reversing

causes.

When submitting a feed the device is switched off

after the issuance of reports malfunction.

Check plug to compound speed sensor rotation.

Check 13 pin connector on the driver site (corrosion).

Open or short closing signal wire to the ESR module.

E-47

First drive running of the EFA exceeded tolerance

lever potentiometer of movement

Unusual behavior movement.

No, the final speed.

Despite the return of movement of the lever ago

speed reduction initially not made (Slow response).

Only the issue of a code, the behavior of the motion is not changes.

Potentiometer movement of the lever It is in the form double potentiometer: permissible meaning

potentiometer

Motion 1:

Neutral Situation: 3,8 - 4.2V

Next: 6.9 - 7.3 in

Previous: 0.8 - 1.2 V

Potentiometer Motion 2 issues opposite signal sum

with which the signal potentiometer

Motion 1 is always must have permanent value.

If the total signal is not in within a predetermined

range, lever potentiometer of movement defective.

 

E-48 

In the feed ESR Metal device

The delivery device It stands load metal detector.

Remove the metal. Is not fault in sense of the word.

 

E-49

ESR Stop slip clutch consoles

STB is turned off. Post without overload:

Check cable set and to console her.

Check sensor rotation speed prefix.


Comments: 0