mercedes benz logo

Make a choice of MERCEDES BENZ Truck Actros, Atego & Axor Fault Codes DTC pages:

 

BS (breaking control system), NR (Frame level adjustment) AG (Automatic gear selection) DTC of MERCEDES Actros, Atego & Axor

 

ABS (Brake system), HZR (Interior heating control) & MR (Engine control) DTC of MERCEDES Actros, Atego & Axor

 

FR (Traffic regulation) & PSM (Special module with parameterization) DTC of MERCEDES Actros, Atego & Axor

 

DTCO (Tachograph), ZHE (Additional heating) & WS (Maintenance system) of MERCEDES Actros, Atego & Axor

 

FLA (Torchlight Device), FTCO (Flat Tachograph Control Unit)) DTC of MERCEDES Actros, Atego & Axor

Download
MERCEDES Actros & Atego Fault Codes DTC
MERCEDES Actros & Atego Fault Codes DTC
MERCEDES Actros & Atego Fault Codes DTC.
Adobe Acrobat Document 235.4 KB

MERCEDES BENZ Actros, Atego, Axor Trucks GS Fault Codes DTC

Mercedes Truck Fault Codes GS Unit

 

0160 CAN bus vehicle has a fault

0161 CAN connection has a malfunction open communication on the CAN bus vehicle

0162 Malfunction of communication with the control unit FR (FMR)

0163 Faulty communication with PSM control unit

0164 Faulty communication with the control unit WSK

0165 Fault RS communication with the control unit (RET)

0166 Faulty communication with the ABS control unit or BS (EPB)

0167 Faulty communication with the control unit INS

0168 Faulty communication with KS control unit (MKR)

0169 Faulty communication with the AG control unit (AGE)

0170 Fault MR communication with the control unit (PLD)

0171 WS Faulty communication with the control unit a fault of communication with the control unit WS (FSS)

1010 Internal error in the control unit

1011 Unreliable data harmonization

1012 GS (EPS) control unit is not correctly parameterized

1080 TEST-TEST-OR Electronics Software

TEST-1081 Computer software

1082 module verification stand zaaktivirovan

1101 Overvoltage at terminal 30

1102 Undervoltage at terminal 30

1201 mass cable for the control unit is open

1301 Overvoltage at terminal 15

1302 Undervoltage at terminal 15

1503 Supply voltage for the joystick is broken

1504 Supply voltage for the joystick has a short to ground

OR

Supply voltage for the joystick and rotary encoder B57 / B99 is a short to ground

OR

Supply voltage for the joystick and rotary encoder B57 has a short to ground

1505 Supply voltage for joystick has short to positive

OR

Supply voltage for the joystick and rotary encoder B57 / B99 has short to positive

OR

Supply voltage for the joystick and rotary encoder B57 has short to positive

2030 Faulty communication with a joystick

2031 cable mass for the joystick is broken

2032 Cable for emergency operation switch is open

2033 Cable for emergency operation switch has a short circuit to ground

OR

weight to the joystick cable is shorted to ground

2034 Cable for emergency operation switch has a short circuit to positive

OR

weight to the joystick cable is short to positive

Error 2035 lifting the ban on the inclusion of an emergency electronics

2036 Switch emergency operation has failed

2037 The final stage includes a feedback fault

GS 3020 block valves (EPS), MS1 solenoid valve is open

GS 3021 block valves (EPS), MS2 solenoid valve is open

3022 Valve GS (EPS), the solenoid valve MS1 has a short to ground

3023 Valve GS (EPS), the solenoid valve MS2 has a short to ground

3024 Valve GS (EPS), the solenoid valve MS1 has short to positive

3025 Valve GS (EPS), the solenoid valve MS2 has short to positive

GS 3120 block valves (EPS), MUB solenoid valve is open

GS 3121 block valves (EPS), the solenoid valve is open MGB

3122 Valve GS (EPS), the solenoid valve MUB is a short to ground

3123 Valve GS (EPS), the solenoid valve MGB has a short to ground

3124 Valve GS (EPS), the solenoid valve MUB has short to positive

3125 Valve GS (EPS), the solenoid valve MGB has short to positive

GS 3220 block valves (EPS), the solenoid valve is open MUE

GS 3221 block valves (EPS), the solenoid valve is open MGE

3222 Valve GS (EPS), the solenoid valve MUE has a short to ground

3223 Valve GS (EPS), the solenoid valve MGE has a short to ground

3224 Valve GS (EPS), the solenoid valve MUE has short to positive

3225 Valve GS (EPS), the solenoid valve MGE has short to positive

GS 3320 block valves (EPS), MG1 solenoid valve is open

GS 3321 block valves (EPS), MG2 solenoid valve is open

3322 Valve GS (EPS), the solenoid valve MG1 has a short to ground

3323 Valve GS (EPS), the solenoid valve MG2 has a short to ground

3324 Valve GS (EPS), the solenoid valve MG1 has short to positive

3325 Valve GS (EPS), the solenoid valve MG2 is short to positive

GS 3420 block valves (EPS), MR1 solenoid valve is open

GS 3421 block valves (EPS), MR2 solenoid valve is open

3422 Valve GS (EPS), the solenoid valve MR1 is a short to ground

3423 Valve GS (EPS), the solenoid valve MR2 has a short to ground

3424 Valve GS (EPS), the solenoid valve MR1 has short to positive

3425 Valve GS (EPS), the solenoid valve MR2 has short to positive

3803 total cable weight of the magnetic valve is open

3804 total cable weight of the magnetic valve has a short to ground

3805 total cable weight of the magnetic valve has a short circuit to positive

4040 divider probe is broken

4041 divider sensor has a short circuit to ground

4042 divider sensor has short to positive

4043 divider functioning Faulty sensor components

4044 Component divider sensor outside the permissible parameters of the border

4140 Sensor switching gear is broken

4141 Sensor switching gear has a short to ground

4142 Sensor switching gear has short to positive

4143 Malfunctioning gear incorporating sensor components

4144 switching gear sensor component is permissible parameters of the border

4240 Sensor switching tracks is broken

4241 Sensor switching tracks is short to ground

4242 Sensor switching tracks has short to positive

4243 Faulty operation runs incorporating sensor components

4244 incorporating the sensor component runs outside the permissible parameters of the border

4340 sensor has a switching range of cliff

4341 Sensor switching range has a short to ground

4342 Sensor switching range has short to positive

4343 Faulty operation range incorporating sensor components

4344 incorporating the sensor component is permissible parameter range border

4440 displacement transducer coupling is broken

4441 Sensor movement clutch has a short to ground

4442 displacement transducer coupling has short to positive

4443 Faulty operation clutch travel sensor components

4444 Component clutch travel sensor outside the permissible parameters of the border

5040 signal from the angle sensor B57 missing

Error 5043 B57 component operation

OR

Error angle sensor operation

5140 B3 speed sensor for the intermediate shaft has broken

OR

The signal from the rotation sensor B3 is absent

5141 B3 speed sensor for the intermediate shaft is a short to ground

5142 B3 speed sensor for the intermediate shaft has a short circuit to positive

OR

B3 speed sensor for the intermediate shaft has an open or short to positive

5143 operation failed speed sensor component for the intermediate shaft

5240 C3 signal / pulse velocity V no

5243 C3 signal / pulse velocity V has a fault

5340 signal from the angle sensor B99 missing

Error 5343 B99 component operation

8091 No speed

8092 Transfer Case parameterized incorrectly or the parameterization process is not carried out

8093 Wrong type gearbox

8094 Estimated direction of movement is not significantly

8095 Position of clutch: a minimum agreed parameter is not reached

OR

TEST-Software

8096 Position of coupling: maximum parameter is exceeded the agreed

OR

TEST-Electronics

Mercedes Truck INS Fault Codes DTC

0101 Sensor supply "filling pressure in the circuit 1 'has a short to ground

0102 Sensor supply "filling pressure in the circuit 1 'has a short circuit to positive

0104 Sensor input signal "pressure filling circuit 1 'does not reach the measuring area

0105 Sensor input signal "pressure filling in the loop 1" is greater than the measurement area

0201 Power Sensor "Filling pressure in circuit 2" is a short to ground

0202 Power Sensor "Filling pressure in circuit 2" has short to positive

0204 Sensor input signal "Filling pressure in circuit 2" does not reach the measuring area

0205 Sensor input signal "pressure filling of circuit 2" is greater than the measurement area

0301 cab locking system has a short circuit to ground

0308 cab locking system is an open or short to positive

0508 Fuel level sensor in the fuel tank is open or short circuit to positive

0607 Input Terminal W is shorted to ground or open

By 0901 cable has a short circuit to ground

By 0902 cable is open or short circuit to positive

1020 CAN vehicle bus fault

1101 Digital input H1.18 / 12 invalid

OR

Digital input status H1.18 / 1 "Front interaxle lock" unreliable

1102 Digital input H1.18 / 11 invalid

OR

Digital input status H1.18 / 2 "differential lock 1.Peredney axis" unreliable

1103 Digital input H1.18 / 10 invalid

OR

Digital input status H1.18 / 3 "reserve funds washer" unreliable

1104 Digital input H3.18 / 11 invalid

OR

Digital input status H1.18 / 4 "axle differential lock 1.Zadney" unreliable

1105 Status of digital input H1.18 / 5 "differential lock 2.Peredney axis" unreliable

1106 Status of digital input H1.18 / 6 "Locking the driver's cab on the left" unreliable

1107 Status of digital input H1.18 / 7 «Differential lock 2.Zadney axis" unreliable

1108 Status of digital input H1.18 / 8 "rear interaxle lock" unreliable

1109 Digital input H1.18 / 9 invalid

OR

Digital input status H1.18 / 9 "Locking the driver's cab on the right" unreliable

1110 Digital input H1.18 / 10 invalid

1111 Status of digital input H1.18 / 11 "PTO" unreliable

1112 Digital input H1.18 / 12 invalid

1113 Status of digital input H1.18 / 13 "Control lamps" unreliable

1114 Status of digital input H1.18 / 14 "oil level in the steering mechanism" unreliable

1115 Status of digital input H1.18 / 15 "trailer ABS fault" unreliable

1116 Status of digital input H2.18 / 9 "Contact us at the door" unreliable

1117 Status of digital input H3.18 / 11 "Steering with hydrostrengthening" unreliable

1118 Status of digital input H3.18 / 12 "The pressure in the circuit filling 4" unreliable

1119 Status inlet H3.18 / 13 "Terminal 58" unreliable

1120 Status of digital input H3.18 / 14 "Reserve" unreliable

1121 Status of digital input H3.18 / 16 "The pressure in the filling circuit 3" unreliable

1122 Status button "Back Zurück» unreliable

1123 The state of "Down Auf» button unreliable

1124 Status button "Up Ab» unreliable

1125 Status button "Selection Auswahl» unreliable

1126 Status button "Reset Reset» unreliable

1127 Status button "Plus Plus» unreliable

1128 Status button "Minus Minus» unreliable

1129 Condition "Set Set» button unreliable

1130 Status "Select Select» button unreliable

1131 Status of digital input H2.18 / 5 "Terminal 15" unreliable

1220 Failure of the connections between the module and the K-module n-

1321 Error in parameterization of K-module

1332 K-module is faulty

1333 K-module is faulty

1421 parameterization error in the control unit

OR

Parameterization error in the n-module

1432 Internal error in the control unit

OR

n-module is faulty

1520 CAN bus to the tachograph is faulty

OR

V-signal from the control unit FR offline

1903 Terminal 15 is open

1941 Overvoltage

OR

Over voltage at terminal 15

1942 Undervoltage at terminal 15

2001 Communication on the exchange of data with the address control unit 1 is broken

2002 Communication on the exchange of data with the control unit FR broken

2003 Communication on the exchange of data with the at 3 control unit is broken

2004 Communication on the exchange of data with the address control unit 4 is broken

2005 Communication on the exchange of data with the SPA control unit is broken

2006 Communication on the exchange of data with the PFA unit is broken

2007 Communication on the exchange of data with the FLA control unit is broken

2008 Communication on the exchange of data with KS control unit is broken

2009 Communication on the exchange of data with the GS control unit is broken

2010 Communication on the exchange of data with the address 10, the control unit is broken

2011 Communication on the exchange of data with the SIR control unit is broken

2012 Communication on the exchange of data with SIL control unit is broken

2013 Communication on the exchange of data with the control unit WSK broken

2014 Communication on the exchange of data with the ABS control unit is broken

2015 Communication on the exchange of data with the RS control unit is broken

2016 Communication on the exchange of data with the address 16, the control unit is broken

2017 Communication on the exchange of data with the control unit NR broken

2018 Communication on the exchange of data with the FFB control unit is broken

2019 Communication on the exchange of data with a ZV or KSA control unit is broken

2020 Communication on the exchange of data with the EKL control unit is broken

2021 Communication on the exchange of data with the address 21, the control unit is broken

2022 Communication on the exchange of data with the address 22, the control unit is broken

2023 Communication on the exchange of data with the address 23, the control unit is broken

2024 Communication on the exchange of data with the WS control unit is broken

2025 Communication on the exchange of data with the address 25, the control unit is broken

2026 Communication on the exchange of data with the KOM control unit is broken

2027 Communication on the exchange of data with the address 27, the control unit is broken

2028 Communication on the exchange of data with the control unit is broken HZR

2029 Communication on the ZHE data exchange with the control unit is broken

2030 Communication on the exchange of data with the address 30, the control unit is broken

2031 Communication on the exchange of data with the HPS control unit is broken

2032 Communication on the exchange of data with the address control unit 32 is broken

2033 Communication on the exchange of data with the address 33 control unit is broken

2034 Communication on the exchange of data with the address 34 of the control unit is broken

2035 Communication on the exchange of data with the address 35 control unit is broken

2036 Communication on the exchange of data with the BS control unit is broken

2037 Communication on the exchange of data with the address 37 control unit is broken

2038 Communication on the exchange of data with the control unit AGE broken

2039 Communication on the exchange of data with the address 39 of the control unit is broken

2040 Communication on the exchange of data with the MR control unit is broken

2041 Communication on the exchange of data with the address 41 of the control unit is broken

2042 Communication on the exchange of data with the SRS control unit is broken

2043 Communication on the exchange of data with the address 43 control unit is broken

2044 Communication on the exchange of data with the EDW control unit is broken

2045 Communication on the exchange of data with the address control unit 45 is broken

2046 Communication on the exchange of data with PSM control unit is broken

2047 Communication on the exchange of data with the control unit SRB broken

2048 Communication on the exchange of data with the address 48 control unit is broken

2049 Communication on the exchange of data with the control unit is broken ART

OR

Communication on the exchange of data with the address 49 control unit is broken

2050-2099 Communication on the exchange of data with the addresses by the control unit from 50 to 99 broken

2100 Communication on the exchange of data with the control unit AGE broken

2101-2104 Communication on the exchange of data with the addresses of the control unit 101 to 104 is broken

2105 Communication on the exchange of data with the ANH control unit is broken

2106-2109 Communication on the exchange of data with the addresses of the control unit 106 to 109 is broken

2110 Communication on the exchange of data with the AUF control unit is broken

2111-2199 Communication on the exchange of data with the addresses of the control unit 111 to 199 is broken

2515 Nor any text data is not put in the toolbar

3001 control unit at 1 defective

3002 FR control unit defective

3003 control unit at 3 defective

3004 control unit at 4 defective

SPA 3005 control unit defective

OR

The control unit 5 at defective

3006 PFA control unit defective

3007 Block FLA control defective

3008 GS Control unit defective

OR

KS control unit defective

3009 GS Control unit defective

3010 control unit at 10 defective

3011 SIR control unit defective

SIL 3012 control unit defective

3013 Block WSK control defective

3014 ABS control unit defective

3015 RS control unit defective

3016 to the address control unit 16 is not working properly

3017 NR control unit defective

3018 block FFB control defective

3018 block ZV control or defective KSA

3020 Block EKL control defective

3021-3023 at the address control unit from 21 to 23 is not working properly

3024 WS control unit defective

3025 control unit at 25 defective

3026 Block KOM control defective

3027 to the address control unit 27 is not working properly

3028 Block HZR control defective

3029 Block ZHE control defective

3030 control unit at 30 defective

3031 Block HPS control defective

3032-3035 at the address control unit from 32 to 35 is not working properly

BS 3036 control unit defective

3037 control unit at 37 defective

3038 block AGE control defective

3039 to the address control unit 39 is not working properly

3040 MR control unit defective

3041 to the address control unit 41 is not working properly

3042 SRS control unit defective

3043 to the address control unit 43 is not working properly

EDW 3044 control unit defective

3045 control unit at 45 defective

3046 PSM control unit defective

3047 Block SRB control defective

3048 at 48 control unit defective

3049 ART control unit defective

OR

The control unit at 49 defective

3050-3099 at the address control unit from 50 to 99 is not working properly

3100 EAB control unit defective

Comments: 2
  • #2

    Hhh (Friday, 10 May 2024 02:52)

    BS 1 4140

  • #1

    Sefu Masha (Friday, 01 March 2024 20:15)

    What did you min. Gs 12 information